PSI Structural Biology Knowledgebase

PSI | Structural Biology Knowledgebase
Header Icons
E-Collection

Related Articles
Families in Gene Neighborhoods
June 2015
Expanding the Reach of SAD
April 2015
Greasing the Path for SFX
January 2015
Time-Resolved Crystallography with HATRX
December 2014
Structures Without Damage
August 2014
Error Prevention
July 2014
A Refined Refinement Strategy
May 2014
Membrane Proteome: Microcrystals Yield Big Data
April 2014
Optimizing Damage
February 2014
Getting Better at Low Resolution
January 2014
Building a Structural Library
November 2013
Drug Discovery: Identifying Dynamic Networks by CONTACT
October 2013
Microbiome: Solid-State NMR, Crystallized
September 2013
Fluorescence- and Chromatography-Based Protein Thermostability Assay
October 2012
Insert Here
October 2012
Native phasing
August 2012
Smaller may be better
April 2012
Metal mates
February 2012
Not so cool
December 2011
One from many
August 2011
Rosetta hone
July 2011
Solutions in the solution
June 2011
Beyond crystals, solutions, and powders
May 2011
Snapshot crystallography
March 2011
FERM-ly bound
February 2011
A new amphiphile for crystallizing membrane proteins
January 2011
'Super-resolution' large complexes
December 2010
Proteinase K and Digalacturonic Acid
September 2010
Some crystals like it hot
May 2010
Tips for crystallizing membrane proteins in lipidic mesophases
February 2010
Tackling the phase problem
November 2009
Crystallizing glycoproteins
September 2009
Crystals from recalcitrant proteins
August 2009
Tips for crystallizing membrane proteins
June 2009
Chaperone-assisted crystallography
March 2009
An “X-ray” ruler
January 2009
Methylation boosts protein crystallization
December 2008

Technology Topics Crystallography

Beyond crystals, solutions, and powders

SBKB [doi:10.1038/sbkb.2011.19]
Technical Highlight - May 2011
Short description: A new approach improves the functionality of an alternative use for synchrotron beams.

Schematic for FTIR imaging using multiple synchrotron beams. 1

Synchrotron beams, the long- and much-appreciated workhorse of structural biologists for X-ray crystallography, small-angle X-ray scattering (SAXS) and other techniques, are perfect for these applications because of their high intensity, high polarization and low angular divergence. However, the stable and bright nature of their radiation also makes them excellent energy sources for other applications, including Fourier transform infrared (FTIR) imaging—a technique that generates images based on the infrared spectrum of biological samples.

FTIR imaging has an advantage over traditional microscopy as it does not require chemical labeling of samples with dyes, stains or tagged biomolecules. Instead, it uses mid-infrared absorption to produce an image by focal plane array (FPA) detection, with no additional processing of the sample needed. The image is determined by how areas of the sample respond to specific infrared wavelengths.

One challenge of FTIR microspectroscopy has been the lack of brightness and spatial resolution available from thermal sources of mid-infrared radiation, the traditional energy sources used in this technique. Previous work addressed this problem by adapting FTIR microspectroscopy to work with a synchrotron beam coupled to a mercury-cadmium-telluride detector (for raster scanning measurements), which led to significant improvements in the signal-to-noise ratio. The downside of the synchrotron approach was the low angular divergence of the synchrotron beam, which necessarily illuminates a small area and led to exceedingly long data collection times. Now, Hirschmugl and colleagues have addressed this issue and improved the utility of FTIR microspectroscopy.

Using a specially designed system, the authors split a fan of synchrotron beam radiation into 12 individual beams that were then bundled to illuminate a larger field of view before being collected by an FPA detector. The end result was a near 100-fold improvement in pixel size relative to thermal radiation sources, which allowed them to identify specific components of tissue samples. Without any additional chemical labeling, the authors were able to distinguish cell types, epithelial and stromal areas in tumor samples, and even high-collagen areas on the basis of their different absorption spectra.

One of the most pronounced benefits of the bundled beam approach was the time necessary for image acquisition. A 280 × 310 μm area required only 30 min for acquisition at diffraction-limited resolution, whereas the previous system using a synchrotron beam source would have required 11 d. The combination of high spatial resolution with substantially improved image acquisition time will undoubtedly make FTIR imaging using a synchrotron multi-beam source a vital technique for researchers looking for detailed images with minimal processing of their samples.

Steve Mason

References

  1. M.J. Nasse et al. High-resolution Fourier-transform infrared chemical imaging with multiple synchrotron beams.
    Nat. Methods (20 March 2011). doi:10.1038/nmeth.1585

Structural Biology Knowledgebase ISSN: 1758-1338
Funded by a grant from the National Institute of General Medical Sciences of the National Institutes of Health