PSI Structural Biology Knowledgebase

PSI | Structural Biology Knowledgebase
Header Icons
E-Collection

Related Articles
Microbiome: Expanding the Gut Gene Catalog
November 2014
Complex Search
September 2014
Repairing a Rift
September 2014
iTRAQing the Ubiquitinome
July 2014
Immunity: Clustering Immunoglobulins
June 2014
Mining Protein Dynamics
May 2014
Design and Discovery: Identifying New Enzymes and Metabolic Pathways
January 2014
Epigenetics: Tracing Histone Demethylase Inhibitors
December 2013
Cancer Networks: Predicting Catalytic Residues from 3D Protein Structures
November 2013
Protein-Nucleic Acid Interaction: Inhibition Through Allostery
July 2013
Infectious Diseases: Targeting Meningitis
May 2013
Protein Interaction Networks: Reading Between the Lines
April 2013
Design and Discovery: A Cocktail for Proteins Without ID
February 2013
Targeting Enzyme Function with Structural Genomics
July 2012
More in one
June 2012
Disordered Proteins
February 2012
RNA Chaperone NMB1681
July 2011
Capsid assembly in motion
April 2011
One at a time
April 2011
A growing family
February 2011
Predicting functions within a superfamily
January 2011
Isoxanthopterin Deaminase
November 2010
Scaling up mutational scanning
November 2010
Alpha/Beta Barrels
October 2010
Mre11 Nuclease
May 2010
Assigning protein function: GeMMA
April 2010
Face off
October 2009

Technology Topics Annotation/Function

Protein Interaction Networks: Reading Between the Lines

SBKB [doi:10.1038/sbkb.2012.136]
Technical Highlight - April 2013
Short description: An additional separation is added to LC-MS to obtain more information about quaternary structure of complexes.

LC-IMS-MS analysis results in signals separated by m/z (y axis) and drift time (x axis). Doublets are signals from heavy/light peptide pairs, but the triplet (shown above) is from a cross-linked homodimeric peptide (signals are from light-light, light-heavy, heavy-light and heavy-heavy pairs, giving a 1:2:1 ratio). Figure courtesy of Joshua Adkins.

Structural proteomics efforts have greatly benefited from the combination of cross-linking and mass spectrometry (MS). In the presence of a cross-linker, adjacent portions of proteins are linked covalently, and subsequent MS analysis identifies those neighboring fragments, providing clues about overall structure.

Complexes with multiple copies of the same protein, however, present the problem of distinguishing intra- from intermolecular cross-links: unless the identified peptides have overlapping, non-repeated sequences, the distinction cannot be made. This challenge has been addressed by mixing heavy-isotope labeled and unlabeled proteins, such that differentially labeled peptides, when cross-linked, result in a distinct MS signature. This approach, mixed-isotope cross-linking (MIX), has now been improved to uniquely identify more intermolecular cross-links.

Adkins and colleagues (Program for the Characterization of Secreted Effector Proteins partnership with MCSG) added ion mobility spectrometry (IMS) to the traditional liquid chromatography (LC)-MS analysis. A mixture of heavy isotope-labeled and unlabeled proteins was allowed to equilibrate in complexes, which was then cross-linked and digested. The resulting peptides were first separated by LC, then by IMS based on ion drift time, and finally by MS based on mass-to-charge ratio (m/z). In contrast to doublet signals arising from the heavy and light forms of unlinked peptides, cross-linked peptides have a quadruplet signal in a 1:1:1:1 ratio; homodimeric peptide pairs have a triplet signal in a 1:2:1 ratio.

LC-IMS-MS data are analogous to a two-dimensional gel, similarly allowing more information to be gleaned: the additional separation reveals data obscured in the MS-only spectrum. Indeed, comparing LC-IMS-MS data and simulated LC-MS data, the authors found that in the LC-MS-only data, signals from cross-linked peptides overlapped with those for unrelated, interfering peaks.

In this proof-of-principle work with homodimeric proteins, many multiplet peaks are distinguishable by sight. The group also developed a software application, called Cross-linking IMS, to automate the search and data analyses, a feature that will be critical for future high-throughput work with large protein complexes. To analyze such complexes using MIX-LC-IMS-MS, the authors suggest MIX-labeling a subset of subunits, or isotopically labeling the cross-linker. With any of these permutations, the additional IMS separation allows confident identification of more peptides.

Irene Kaganman

References

  1. E.D. Merkley et al. Mixed-Isotope Labeling with LC-IMS-MS for Characterization of Protein–Protein Interactions by Chemical Cross-Linking.
    J. Am. Soc. Mass Spectrom. (19 February 2013). doi:10.1007/s13361-012-0565-x

Structural Biology Knowledgebase ISSN: 1758-1338
Funded by a grant from the National Institute of General Medical Sciences of the National Institutes of Health